Blog

Precautions for installing solid wood wall panels

1. Keep the wall clean
Before installation, the wall surface should be clean, dry, and flat. The height should be marked with a line to level it. In order to adapt to the local climate conditions and achieve the moisture content of the air, the purchased wall panels should be unpacked and stored on site for at least 48 hours before installation.


2. Design the dimensions in advance
Before installing the panel, the block size should be designed first, and each block should be straightened and aligned before trial installation. After adjustment and repair, it should be formally nailed to avoid the surface layer's pattern disorder, uneven color, uneven edges, uneven surface, black lines at the joints, and loose joints.


3. Wire inspection of top plate
Before operation, the top of the protective wall panel should be checked for straightness by pulling a line, and any problems should be corrected in a timely manner. Avoid uneven thickness, height, and splitting of the top strip of the protective wall panel.


4. The wall needs to be treated with moisture-proof measures
Due to the high moisture content of wood, it is prone to shrinkage after drying, resulting in loose, uneven or cracked joints. Therefore, if the wall is damp, it should be constructed after it has dried or treated with moisture-proof measures.


5. Leave gaps on the surface of the panel
The height difference on the surface of the protective wall panel should be less than 0.5mm; The width of the gap between the board surfaces should be uniform and consistent, and the dimensional deviation should not exceed 2mm; The diagonal length deviation of a single panel shall not exceed 2mm; The verticality deviation of the panel shall not exceed 2mm.


6. The corners of yin and yang should be horizontal and vertical
The internal and external corners of the protective wall panel are the key and difficult points of construction, and special attention should be paid. It is necessary to ensure that the internal and external corners are vertical and horizontal, and the joint seam is 45 °.


7. The skirting board and pressure strip should be tightly attached to the panel
The skirting board and pressure strip should be tightly attached to the panel without leaving excessive gaps. The spacing between nails used to fix kickboards or pressure strips should generally not exceed 300mm; The nail cap shall be flattened, and the depth into the Flat noodles shall be 0.5~1.0mm. The nail hole shall be leveled with oily putty of the same color.

 

You Might Also Like

Send Inquiry

在线客服